Skip to content
TaxhintAdvisors
Fire safety · Haryana

Fire NOC in Haryana — Fire Scheme Approval & Fire Safety Certificate

A fire NOC in Haryana comes in two stages under the Haryana Fire and Emergency Services Act, 2022: approval of the fire fighting scheme before you build, and a fire safety certificate once the building and its fire systems are ready. High-rise buildings and special buildings such as factories, schools, hotels and offices above set size limits need both.

Fire scheme approval before constructionFire safety certificate after inspectionValid 3 or 5 yearsAnnual self-declaration
5000+ businesses served10+ years of practice · Pan-India
Get a free consultationWe reply within one working day

What it is

A fire NOC is the fire department’s confirmation that your building meets the fire safety requirements of the law. In everyday use, “fire NOC” covers two approvals: approval of the fire fighting scheme (the drawings), and the fire safety certificate, issued after the finished building is inspected.

In Haryana, the law is the Haryana Fire and Emergency Services Act, 2022, which repealed the Haryana Fire Service Act, 2009. Section 18 deals with the fire fighting scheme, Section 19 with the fire safety certificate and Section 20 with renewal. Applications go to the Director or an officer he authorises, in the form and with the fee prescribed by the rules. The fire measures themselves follow Part IV of the National Building Code of India.

Who it applies to

Check the height first

All high-rise buildings need fire scheme approval under Section 18(2)(a), except residential buildings up to 16.5 metres in height.

Check the floor area: 500 sq m on any floor

Hotel, educational, institutional, business, mercantile, industrial, storage, hazardous and mixed occupancies need it where floor area is more than 500 square metres on any one or more floors. In plain terms: factories, offices, shops, hotels and godowns.

Check the use and the basements

Educational and institutional buildings 9 metres or taller, all assembly buildings, buildings with more than 300 square metres of incidental assembly occupancy on a floor, and buildings with two or more basements, or one basement over 500 square metres. A school run by a Section 8 company is covered just like any other.

Why it matters

Get your occupation certificate

Section 19(5) says no authority may issue an occupation certificate for these buildings unless the fire safety provisions are complied with. No fire safety certificate, no occupation certificate.

Protect the people inside

The inspection checks the fire safety installations and means of escape against the approved scheme. In a fire, those are what get people out.

Satisfy tenants and lenders

Tenants, lenders and insurers often ask to see a valid fire safety certificate before they sign. A current one keeps those conversations short.

Provisional vs final fire NOC at a glance

Fire fighting scheme approval (“provisional NOC”)Fire safety certificate (“final NOC”)
SectionSection 18Section 19; renewal under Section 20
WhenBefore constructionAfter construction and installation of fire systems
What is checkedDrawings and the proposed fire fighting schemeThe building on site, by inspection, against the approved scheme
Validity5 years for high-rise buildings; 2 years for special buildings3 years for high-rise and special buildings; 5 years for residential buildings above 16.5 metres
Renewal and changesRevised scheme after alterations beyond Haryana Building Code limitsRenewed for 3 years at a time; ceases after such alterations

The Act does not use the words “provisional” and “final”. Builders, banks and architects do, and they mean these two approvals. If your architect asks for a provisional fire NOC, it is the fire fighting scheme approval under Section 18.

Here is the catch: a building can move into the list later. Picture a Faridabad private school in a two-storey building just under 9 metres tall. It adds a floor, crosses 9 metres, and is now an educational building that needs fire scheme approval and a fire safety certificate. Plan the fire approvals before the new floor goes up, not after.

Documents required

For fire scheme approval

  • Building plans with floor areas, heights and occupancy
  • Fire fighting scheme drawings: exits, staircases, hydrants, sprinklers, alarms
  • Site plan showing the approach road
  • Proof of ownership or lease of the land

For the fire safety certificate

  • Copy of the approved fire fighting scheme
  • Details of the fire systems installed, as built
  • Details of the Fire Safety Officer, where one is appointed

For renewal

  • Current fire safety certificate
  • Annual self-declarations already given
  • Confirmation that there has been no addition or alteration beyond Haryana Building Code limits

How it works

1

Check which category your building falls in

We check height, floor area per floor, occupancy and basements against Section 18(2). Take a Faridabad auto-parts unit with a single-storey shed of 600 square metres. It is low and has no basement, but the floor area alone crosses 500 square metres, so it needs both approvals.

2

Apply for fire fighting scheme approval

Before construction, the scheme goes to the Director or an authorised officer with the prescribed fee. The officer scrutinises it and approves or rejects it with reasons.

3

Build and install as per the scheme

Your contractor builds and installs the fire systems exactly as approved. Any change in the drawings should go back for approval first.

4

Apply for the fire safety certificate

On completion, the owner applies under Section 19(1). The officer inspects the fire safety installations and means of escape and reports to the Director, who grants or rejects the certificate.

5

Give self-declarations and renew on time

Every year the owner or occupier gives a self-declaration that the system works and nothing has been altered. In practice, this is the step owners forget. We diarise it with the renewal under Section 20 as part of our compliance management work.

Timelines

Build within the scheme’s validity

Under Section 18(3), fire fighting scheme approval is valid for five years for high-rise buildings and two years for special buildings. Two years passes quickly on a factory project.

Renew the certificate on time

Under Section 19(4), the fire safety certificate is valid for three years for high-rise and special buildings, and five years for residential buildings above 16.5 metres. Each renewal under Section 20(3) is for three years.

Self-declare every year

Sections 19(6) and 20(4) require an annual self-declaration that the fire fighting system works and the building has not been altered. The Fire Officer may check at random.

What happens if you skip it

Risk prosecution under Section 30

Contravening the Act can mean imprisonment of up to three months, a fine of up to ₹10,000, or both, plus up to ₹1,000 for every day a continuing offence goes on. Section 31 extends liability to the officers of a company.

Lose the certificate, or the building

A certificate can be cancelled under Section 21 if directions are not followed, after a hearing. Under Section 47, a dangerous building can have its electricity and water cut, occupants removed and the premises sealed.

Pay by the square metre

If you do not appoint a Fire Safety Officer within 30 days of a notice, Section 26 charges ₹10 to ₹50 per square metre of the area you own or occupy, for every month of default.

Frequently asked questions

Which buildings need a fire NOC in Haryana?

Section 18(2) of the Haryana Fire and Emergency Services Act, 2022 lists them. All high-rise buildings need it, except residential buildings up to 16.5 metres. So do hotel, educational, institutional, business, mercantile, industrial, storage, hazardous and mixed-use buildings with more than 500 square metres on any floor, educational and institutional buildings 9 metres or taller, all assembly buildings, buildings with over 300 square metres of incidental assembly use on a floor, and buildings with two basements or one basement over 500 square metres. We check your building against each clause.

What is the difference between a provisional and a final fire NOC?

The provisional fire NOC is the approval of the fire fighting scheme under Section 18, taken before construction on the basis of drawings. The final fire NOC is the fire safety certificate under Section 19, issued after the building and its fire systems are inspected. You need the first before you build and the second before you occupy.

How long is a fire NOC valid in Haryana?

The fire safety certificate is valid for three years for high-rise and special buildings, and five years for residential buildings above 16.5 metres, under Section 19(4). Each renewal under Section 20 is valid for three years. Fire fighting scheme approval has its own validity: five years for high-rise buildings and two years for special buildings. We track both dates so nothing lapses quietly.

Does a small factory or shop need a fire NOC?

Not under Section 18(2) if the building stays below every limit: it is not a high-rise, has no more than 500 square metres on any floor, stays within the basement limits and has no assembly use. But Section 18(1) still requires every owner or occupier to provide and maintain fire fighting installations and life safety measures under the National Building Code. We measure your building against each limit with you before you decide.

Can I get an occupation certificate without a fire NOC?

No. Section 19(5) says that, notwithstanding any other state law, no authority empowered to issue an occupation certificate for these buildings shall issue it unless the fire safety certificate provisions are complied with. So the fire safety certificate comes before the occupation certificate. We plan the fire inspection into your completion schedule, so the occupation certificate is not held up.

What happens if I add a floor or alter the building later?

If the addition or alteration goes beyond what the Haryana Building Code, 2017 permits, the fire safety certificate ceases to exist under Section 19(6). You must then apply for approval of a revised fire fighting scheme under Section 18. The same rule applies to a renewed certificate under Section 20(4). Tell us before the work starts, and we will get the revised scheme approved in time.

What is the annual self-declaration?

Every year, the owner or occupier must give a self-declaration that the fire fighting system installed in the building is working in good condition and that there has been no addition or alteration. This is required by Section 19(6), and again by Section 20(4) after renewal. The Fire Officer may check buildings at random. We send you a reminder and the declaration format each year.

What is the penalty for breaking the fire safety rules?

Under Section 30, contravening the Act can lead to imprisonment of up to three months, a fine of up to ₹10,000, or both, with up to ₹1,000 a day for a continuing offence. Failing to appoint a Fire Safety Officer within 30 days of a notice attracts ₹10 to ₹50 per square metre each month under Section 26. Staying compliant costs far less than either.

Who inspects the building for the fire safety certificate?

The officer handling the application inspects the building under Section 19(2), checking the fire safety installations and means of escape against the approved scheme. The officer reports to the Director or an authorised officer, who grants or rejects the certificate with reasons. Renewal under Section 20(2) involves a fresh inspection. We walk the site with you beforehand, so there are no surprises on the day.

Pricing

What it costs

Our fee plus the government fee that applies to your case, quoted before you commit. Tell us the situation and we will price it exactly.

Ready to begin?

Share your building’s height, floor areas and use, and we will tell you which fire approvals you need and get them in place.